Dedicated Micros ©2009
16
EcoSense
Step 8 Connecting DM Oracle, 2060 & 2040 Domes
A DM Oracle, 2040 or 2060 Dome can be connected via RS485 twisted pair cabling.
The dome address should be set according to the camera number of unit (1-16).
Pin connections for RS485 connection to a Dennard dome on serial port 2 are:
Dome Cable Pin Connections
Yellow 1 TX+
Green 9 TX-
Step 9 Connecting Power
Connect the 12v DC power adaptor (supplied) to the unit and then to the wall socket, or to a
fused spur connection. To be compliant with wiring regulations in some countries, an Alarm/
Security device should be connected to a fused spur and not a wall outlet socket (check local
regulations before installation).